MAKINDO MEDICINE · Statistics & Evidence-Based MedicineClinical textbook
Statistics: Diagnostic tests, screening and Bayes' theorem
📊 Diagnostic tests, screening and Bayes' theorem. Every test result changes a probability rather than delivering a certainty. Sensitivity, specificity, predictive values and likelihood ratios are among the most examined statistics in the UKMLA and MRCP, and they are used every day when interpreting D-dimers, troponins, FIT and screening results. This chapter shows how to calculate and interpret them, and why the same test behaves differently in general practice and in a specialist clinic. Your four questions for any test result: What was the probability of disease before the test? How good is the test (sensitivity, specificity, likelihood ratio)? What is the probability now? Will the result change what I do?
The 2 × 2 Table
Test result
Disease present
Disease absent
Total
Positive
a - true positive (TP)
b - false positive (FP)
a + b
Negative
c - false negative (FN)
d - true negative (TN)
c + d
Total
a + c
b + d
N
Always draw the table - with columns for disease status (the reference standard) and rows for the test result.
Prevalence = (a + c) ÷ N.
In exams, if given prevalence, sensitivity and specificity, construct the table from a convenient population (e.g. 1,000 or 10,000).
Sensitivity and Specificity
Sensitivity = a ÷ (a + c) = TP ÷ all with disease - the proportion of people with the disease who test positive.
Specificity = d ÷ (b + d) = TN ÷ all without disease - the proportion of people without the disease who test negative.
They are properties of the test and are (in principle) independent of prevalence, although they vary with the spectrum of disease (see spectrum bias).
SnNOut: a highly Sensitive test, when Negative, rules Out (few false negatives) - e.g. D-dimer in low-probability PE, CT head within 6 hours for subarachnoid haemorrhage.
SpPIn: a highly Specific test, when Positive, rules In (few false positives) - e.g. Koplik spots for measles, anti-CCP for rheumatoid arthritis.
Positive predictive value (PPV) = a ÷ (a + b) - of those testing positive, the proportion who have the disease.
Negative predictive value (NPV) = d ÷ (c + d) - of those testing negative, the proportion who do not.
Predictive values depend on prevalence (pre-test probability):
Low prevalence (screening, general practice) → PPV falls (many false positives) and NPV rises.
High prevalence (specialist clinic) → PPV rises and NPV falls.
This is why a positive troponin in a young adult with atypical chest pain, or a positive screening test in a low-risk population, is often a false positive.
Accuracy = (a + d) ÷ N - can be misleading when prevalence is very low or very high.
Likelihood Ratios
LR+ = sensitivity ÷ (1 − specificity) - how much more likely a positive result is in someone with the disease than without.
LR− = (1 − sensitivity) ÷ specificity - how much less likely a negative result is in someone with the disease.
Interpretation:
LR+
LR−
Effect on probability
>10
<0.1
Large, often conclusive change
5–10
0.1–0.2
Moderate change
2–5
0.2–0.5
Small change
1–2
0.5–1
Rarely important
1
1
No change - useless test
LRs do not depend on prevalence and can be applied to an individual's pre-test probability.
Multi-level LRs use several result bands (e.g. ferritin levels, Wells score categories).
Pre-test Probability, Bayes and the Fagan Nomogram
Converting: odds = probability ÷ (1 − probability); probability = odds ÷ (1 + odds).
Steps: estimate pre-test probability (from prevalence, clinical features or a score such as Wells) → convert to odds → multiply by LR → convert back to probability.
Fagan nomogram - a graphical way to do this: draw a line from the pre-test probability through the LR to read the post-test probability.
Test and treatment thresholds: if the post-test probability will not cross the threshold at which management changes, the test is not worth doing. Below the "test threshold" - do not test; above the "treatment threshold" - treat without testing.
Clinical example: Wells "PE unlikely" + negative D-dimer → probability low enough to stop; "PE likely" → go straight to CTPA because a negative D-dimer would not lower the probability enough.
Cut-offs, Trade-offs and ROC Curves
For continuous tests (e.g. BNP, PSA, HbA1c), moving the cut-off trades sensitivity against specificity: a lower threshold increases sensitivity and decreases specificity.
Receiver operating characteristic (ROC) curve - plots sensitivity (true positive rate) against 1 − specificity (false positive rate) for every cut-off.
Area under the curve (AUC, c-statistic) - 0.5 = no better than chance; 0.7–0.8 = acceptable; 0.8–0.9 = excellent; 1.0 = perfect discrimination. Also used to describe risk prediction models (e.g. QRISK3).
Choosing the cut-off depends on the consequences: high sensitivity when missing disease is dangerous (sepsis screening, rule-out tests); high specificity when false positives lead to harmful treatment or invasive tests (confirmation tests).
Calibration (agreement between predicted and observed risk) matters as well as discrimination for risk scores.
Combining Tests - Serial and Parallel
Serial (sequential) testing - a second test only if the first is positive (e.g. screening test then diagnostic test). Overall specificity rises, sensitivity falls. Used in screening programmes (e.g. HIV antibody screen then confirmatory test).
Parallel testing - several tests at once; disease suspected if any is positive. Overall sensitivity rises, specificity falls. Used when missing disease is dangerous (e.g. troponin with ECG).
LRs from independent tests can be multiplied sequentially (assumes conditional independence - often not true in practice).
Diagnostic Accuracy Studies and Their Biases
Design: a consecutive or random series of patients in whom the diagnosis is uncertain, each receiving both the index test and the reference ("gold") standard, interpreted blind.
Spectrum bias - testing very sick cases against healthy controls inflates sensitivity and specificity; the test must be evaluated in the population where it will be used.
Verification (work-up) bias - only those with positive tests receive the reference standard.
Incorporation bias - the index test is part of the reference standard.
Review bias - the reference standard is interpreted with knowledge of the index test (or vice versa).
Imperfect reference standard - misclassification biases accuracy estimates.
Reporting: STARD guidelines; quality assessment with QUADAS-2.
Screening Statistics
Screening tests are applied to asymptomatic populations with low prevalence, so PPV is often low - most positives are false positives (e.g. mammography PPV is around 10–20%).
Uptake (coverage) - the proportion of the eligible population screened; programmes depend on high, equitable uptake.
Detection rate and interval cancers (cancers arising between screens) measure programme performance.
Numbers needed to screen (NNS) - number who must be screened to prevent one death from the disease.
Overdiagnosis - detection of disease that would never have caused symptoms or death in the person's lifetime (e.g. some DCIS, low-grade prostate cancer, small thyroid cancers); results in overtreatment.
Wilson and Jungner criteria and the UK NSC criteria are covered in the Public Health chapters.
Screening Biases
Lead-time bias - earlier diagnosis makes survival time from diagnosis look longer even if the date of death is unchanged. Solution: compare mortality rates (not survival from diagnosis) in randomised trials.
Length-time bias - screening preferentially detects slow-growing, less aggressive disease (longer pre-clinical phase), making screen-detected cases appear to do better.
Overdiagnosis bias - inclusion of indolent disease inflates apparent survival.
Healthy volunteer (selection) bias - people who attend screening are healthier and more health-conscious than non-attenders.
The best evidence for a screening programme is a randomised trial showing reduced disease-specific and all-cause mortality.
Bayes: pre-test probability 20% → odds 0.25; positive result (LR+ 18) → post-test odds 4.5 → probability 4.5 ÷ 5.5 = 82%. Negative result (LR− 0.105) → odds 0.026 → probability 2.6%.
Table from figures: 100 patients with MI, test positive in 80; 400 without MI, test negative in 360. Sensitivity = 80/100 = 80%; specificity = 360/400 = 90%; PPV = 80 ÷ (80 + 40) = 66.7%.
Exam-style Scenarios
Scenario. A new rapid test for influenza has sensitivity 70% and specificity 98%. In winter, prevalence among patients with flu-like illness is 40%; in summer it is 2%. How does the PPV change?
Answer: Winter (per 1,000): TP 280, FP 12 → PPV 96%. Summer: TP 14, FP 19.6 → PPV about 42%. Sensitivity and specificity are unchanged; PPV falls with prevalence.
Scenario. A D-dimer assay has sensitivity 97% and specificity 40%. What is it useful for?
Answer: Ruling out VTE in patients with low pre-test probability (SnNOut; LR− ≈ 0.075). A positive result is unhelpful (LR+ ≈ 1.6) and should not be used to diagnose.
Scenario. A screening programme reports that 5-year survival after diagnosis improved from 50% to 70%, but disease-specific mortality is unchanged. Explain.
Answer: Lead-time bias (diagnosis earlier without delaying death), length-time bias and overdiagnosis - survival from diagnosis is not a valid measure of screening benefit.
Scenario. A clinician estimates a 10% probability of appendicitis. An ultrasound has LR+ 9 and LR− 0.3. What are the post-test probabilities?
Answer: Pre-test odds 0.111. Positive: 0.111 × 9 = 1.0 → 50%. Negative: 0.111 × 0.3 = 0.033 → 3.2%.
Key Points
Draw the 2 × 2 table every time.
Sensitivity and specificity are test properties; predictive values depend on prevalence.
SnNOut and SpPIn.
Post-test odds = pre-test odds × LR; LRs are the most useful way to apply a test to an individual.
In low-prevalence settings most positive results are false positives.
Screening benefit must be judged by mortality in RCTs, not survival from diagnosis.
Guidelines and Further Reading
STARD 2015: Standards for Reporting Diagnostic Accuracy Studies
QUADAS-2: quality assessment of diagnostic accuracy studies
Fagan TJ. Nomogram for Bayes's theorem. NEJM 1975
Sackett DL et al. Evidence-Based Medicine: How to Practice and Teach EBM
UK National Screening Committee: criteria for appraising screening programmes